Σάββατο 7 Μαΐου 2016

Analysis of Polish Vowels of Tracheoesophageal Speakers

Publication date: Available online 6 May 2016
Source:Journal of Voice
Author(s): Marzena Mięsikowska
Objectives/HypothesisThe aim of this study was to determine the acoustical differences between normal and tracheoesophageal Polish speakers during Polish vowel production.MethodsFormant frequencies, namely, the first (F1) and second (F2) formant frequencies for 6 Polish vowels produced by 11 normal and 11 tracheoesophageal speakers, were analyzed using statistical analysis of variance and discriminant analysis.ResultsSpectral analysis showed that the F1 and F2 values of Polish vowels produced by tracheoesophageal speakers were significantly higher than those produced by normal speakers, with the exception of the F2 value of /i/ produced by tracheoesophageal speakers. Analysis of variance showed significant differences between speeches based on the F1 and F2 formant frequencies. Discriminant analysis based on the formant frequencies for F1 and F2 exhibited 73.33% of the mean classification score for tracheoesophageal speakers and 96.36% for normal speakers.ConclusionsTracheoesophageal speakers exhibit higher F1 and F2 formant frequencies, with the exception of the F2 value for the vowel /i/ than normal speakers. Discriminant analysis showed that the classification process for TE speech exhibits lower accuracy due to the poorer classification of the vowels /i/, /u/, and /y/.



from Swallowing and Swallowing Disorders (Dysphagia) via a.lsfakia on Inoreader http://ift.tt/1rzKCwy