Objectives/Hypothesis
To contrast the changes in measurement of the hypoglossal/lingual artery neurovascular bundle (HLNVB) to constant surface landmarks in the base of tongue (BOT) during surgically simulated retraction versus resting anatomic position, and to identify a safe zone for BOT robotic surgery to avoid injury to the HLNVB.
Study Design
Human cadaver study.
Methods
Five fresh-frozen head and neck complexes were obtained, and seven HLNVBs were dissected. A microcaliper was used to measure the distance from the HLNVB to constant surface landmarks in resting and surgically simulated positions using a Feyh-Kastenbauer retractor.
Results
Measurements from foramen cecum to palatoglossus muscle (P < 0.042) was significantly different when comparing anatomical to surgically simulated positions. Importantly, the location of the lingual artery in reference to the surface landmarks measured was dramatically altered with tongue retraction. With retraction, the branches of the dorsal lingual artery were not encountered posterior to a horizontal line between midway circumvallate papilla (mCVP).
Conclusion
Measurements of the HLNVB to surface landmarks in the BOT differs significantly between resting and a surgically simulated tongue position. The dorsal branch of the lingual artery seems more superficial in the BOT than previously described. A safe zone may exist posterior to an imaginary horizontal line between mCVP; however, further studies are needed to confirm this.
Level of Evidence
N/A. Laryngoscope, 2016
from #ORL via xlomafota13 on Inoreader http://ift.tt/1NYNahL
via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου