This study was conducted from January 2015 to September 2016 at a cochlear implant centre in a tertiary referral hospital. Slit incision in the anterosuperior quadrant of the RWM was done in 70 cases, While RWM cruciate incision was done in 48 cases. Of the 48 patients who underwent RWM cruciate incision, 13 cases had no problem, while in 35 cases, we faced difficult insertion. When slit incision of the RWM was done (70 cases), 68 cases showed smooth insertion, meanwhile, we faced increased operative time due to flopping of the electrode in 2 cases only. Moreover, residual low-frequency hearing preservation was more achieved when slit incision of the RWM was done. Tensile strength of the round window membrane after slit incision of the RWM offers support to slim electrodes during introduct...