Πέμπτη 1 Σεπτεμβρίου 2016

Dietary carbohydrate intake, insulin resistance and gastro-oesophageal reflux disease: a pilot study in European- and African-American obese women

Summary

Background

Although obesity rates are higher in African-American than European-American women, gastro-oesophageal reflux disease (GERD) and its comorbidities are more prevalent in European-American women. A common denominator for increased adiposity, and consequent insulin resistance, is excess dietary macronutrient intake – which may promote greater prevalence and severity of GERD in women.

Aim

To investigate whether GERD is more robustly associated with dietary carbohydrate intake, particularly dietary simple carbohydrate intake, and insulin resistance in European-American women.

Methods

About 144 obese women were assessed at baseline and 16 weeks after consuming a high-fat/low-carbohydrate diet. GERD diagnosis and medication usage was confirmed in medical records with symptoms and medications assessed weekly.

Results

About 33.3% (N = 33) of European-American and 20.0% (N = 9) of African-American women had GERD at baseline. Total carbohydrate (r = 0.34, P < 0.001), sugars (r = 0.30, P = 0.005), glycaemic load (r = 0.34, P = 0.001) and HOMAIR (r = 0.30, P = 0.004) were associated with GERD, but only in European-American women. In response to high-fat/low-carbohydrate diet, reduced intake of sugars was associated with reduced insulin resistance. By the end of diet week 10, all GERD symptoms and medication usage had resolved in all women.

Conclusions

GERD symptoms and medication usage was more prevalent in European-American women, for whom the relationships between dietary carbohydrate intake, insulin resistance and GERD were most significant. Nevertheless, high-fat/low-carbohydrate diet benefited all women with regard to reducing GERD symptoms and frequency of medication use.



from #Esophageal Cancer via a.lsfakia on Inoreader http://ift.tt/2bK10Cz
via IFTTT

Electrically Evoked Auditory Event-Related Responses in Patients with Auditory Brainstem Implants: Morphological Characteristics, Test-Retest Reliability, Effects of Stimulation Level, and Association with Auditory Detection.

wk-health-logo.gif

Objective: This study aimed to (1) characterize morphological characteristics of the electrically evoked cortical auditory event-related potentials (eERPs) and explore the potential association between onset eERP morphology and auditory versus nonauditory stimulation; (2) assess test-retest reliability of onset eERPs; (3) investigate effects of stimulation level on onset eERPs; and (4) explore the feasibility of using the onset eERP to estimate the lowest stimulation level that can be detected for individual stimulating electrodes in patients with auditory brainstem implants (ABIs). Design: Study participants included 5 children (S1 to S5) and 2 adults (S6 to S7) with unilateral Cochlear Nucleus 24M ABIs. Pediatric ABI recipients ranged in age from 2.6 to 10.2 years (mean: 5.2 years) at the time of testing. S6 and S7 were 21.2 and 24.6 years of age at the time of testing, respectively. S6 and S7 were diagnosed with neurofibromatosis II (NF2) and implanted with an ABI after a surgical removal of the tumors. All pediatric subjects received ABIs after being diagnosed with cochlear nerve deficiency. The lowest stimulation level that could be detected (behavioral T level) and the estimated maximum comfortable level (C level) was measured for individual electrodes using clinical procedures. For electrophysiological measures, the stimulus was a 100-msec biphasic pulse train that was delivered to individual electrodes in a monopolar-coupled stimulation mode at stimulation levels ranging from subthreshold to C levels. Electrophysiological recordings of the onset eERP were obtained in all subjects. For studies evaluating the test-retest reliability of the onset eERP, responses were measured using the same set of parameters in two test sessions. The time interval between test sessions ranged from 2 to 6 months. The lowest stimulation level that could evoke the onset eERP was defined as the objective T level. Results: Onset eERPs were recorded in all subjects tested in this study. Inter- and intrasubject variations in morphological characteristics of onset eERPs were observed. Onset eERPs with complex waveforms were recorded for electrodes that evoked nonauditory sensations, based on feedback from subjects, as well as for electrodes without any indications of nonauditory stimulations. Onset eERPs in patients with ABIs demonstrated good test-retest reliability. Increasing stimulation levels resulted in increased eERP amplitudes but showed inconsistent effects on response latencies in patients with ABIs. Objective and behavioral T levels were correlated. Conclusions: eERPs could be recorded in both non-NF2 and NF2 patients with ABIs. eERPs in both ABI patient groups show inter- and intrasubject variations in morphological characteristics. However, onset eERPs measured within the same subject in this study tended to be stable across study sessions. The onset eERP can potentially be used to estimate behavioral T levels in patients with ABIs. Further studies with more adult ABI recipients are warranted to investigate whether the onset eERP can be used to identify electrodes with nonauditory stimulations. Copyright (C) 2016 Wolters Kluwer Health, Inc. All rights reserved.

from #Audiology via xlomafota13 on Inoreader http://ift.tt/2cgWEqZ
via IFTTT

Lateralization of Interaural Level Differences with Multiple Electrode Stimulation in Bilateral Cochlear-Implant Listeners.

wk-health-logo.gif

Objective: There is currently no accepted method of mapping bilateral cochlear-implant (BiCI) users to maximize binaural performance, but the current approach of mapping one ear at a time could produce spatial perceptions that are not consistent with a sound's physical location in space. The goal of this study was to investigate the perceived intracranial lateralization of bilaterally synchronized electrical stimulation with a range of interaural level differences (ILDs) and to determine a method to produce relatively more centered auditory images when provided multielectrode stimulation. Design: Using direct stimulation, lateralization curves were measured in nine BiCI listeners using 1000-pulses per second (pps), 500-msec constant-amplitude pulse trains with ILDs that ranged from -20 to +20 clinical current units (CUs). The stimuli were presented bilaterally at 70 to 80% of the dynamic range on single or multiple electrode pairs. For the multielectrode pairs, the ILD was applied consistently across all the pairs. The lateralization response range and the bias magnitude at 0 CU ILD (i.e., the number of CUs needed to produce a centered auditory image) were computed. Then the levels that elicit a centered auditory image with single-electrode stimulation were used with multielectrode stimulation to determine if this produced fewer significant biases at 0 CU ILD. Lastly, a multichannel ILD processing model was used to predict lateralization for the multielectrode stimulation from the single-electrode stimulation. Results: BiCI listeners often perceived both single- and multielectrode stimulation at 0-CU ILD as not intracranially centered. For single-electrode stimulation, 44% of the lateralization curves had relatively large (>=5 CU) bias magnitudes. For the multielectrode stimulation, 25% of the lateralization curves had large bias magnitudes. After centering the single-electrode pairs, the percentage of multielectrode combinations that produced large biases significantly decreased to only 4% (p

from #Audiology via xlomafota13 on Inoreader http://ift.tt/2c6BslC
via IFTTT

Τετάρτη 31 Αυγούστου 2016

Book Review: Laryngeal Physiology for the Surgeon and Clinician: Second Edition

alertIcon.gif

Publication date: Available online 30 August 2016
Source:Journal of Voice
Author(s): Amanda Hu




from #Audiology via xlomafota13 on Inoreader http://ift.tt/2cgFBoT
via IFTTT

A Preliminary Investigation of the Air-Bone Gap: Changes in Intracochlear Sound Pressure With Air- and Bone-conducted Stimuli After Cochlear Implantation.

Hypothesis: A cochlear implant electrode within the cochlea contributes to the air-bone gap (ABG) component of postoperative changes in residual hearing after electrode insertion. Background: Preservation of residual hearing after cochlear implantation has gained importance as simultaneous electric-acoustic stimulation allows for improved speech outcomes. Postoperative loss of residual hearing has previously been attributed to sensorineural changes; however, presence of increased postoperative ABG remains unexplained and could result in part from altered cochlear mechanics. Here, we sought to investigate changes to these mechanics via intracochlear pressure measurements before and after electrode implantation to quantify the contribution to postoperative ABG. Methods: Human cadaveric heads were implanted with titanium fixtures for bone conduction transducers. Velocities of stapes capitulum and cochlear promontory between the two windows were measured using single-axis laser Doppler vibrometry and fiber-optic sensors measured intracochlear pressures in scala vestibuli and tympani for air- and bone-conducted stimuli before and after cochlear implant electrode insertion through the round window. Results: Intracochlear pressures revealed only slightly reduced responses to air-conducted stimuli consistent with previous literature. No significant changes were noted to bone-conducted stimuli after implantation. Velocities of the stapes capitulum and the cochlear promontory to both stimuli were stable after electrode placement. Conclusion: Presence of a cochlear implant electrode causes alterations in intracochlear sound pressure levels to air, but not bone, conducted stimuli and helps to explain changes in residual hearing noted clinically. These results suggest the possibility of a cochlear conductive component to postoperative changes in hearing sensitivity. Copyright (C) 2016 by Otology & Neurotology, Inc. Image copyright (C) 2010 Wolters Kluwer Health/Anatomical Chart Company

from #Audiology via xlomafota13 on Inoreader http://ift.tt/2csBPtO
via IFTTT

Development of a Squelch Effect in Adult Patients After Simultaneous Bilateral Cochlear Implantation.

Objectives: To investigate whether a squelch effect occurs in the first 3 years after simultaneous bilateral cochlear implantation and to investigate whether this effect increases during follow-up. Study Design: Prospective study as part of a multicenter randomized controlled trial that compares simultaneous bilateral cochlear implantation to sequential and unilateral cochlear implantation. Setting: Tertiary referral center. Patients: Nineteen postlingually deafened adults. Intervention: Simultaneous bilateral cochlear implantation. Main Outcome Measure: The squelch effect, measured yearly with a speech-intelligibility-in-noise test with spatially separated sources. Bilateral results were compared to unilateral results in which the cochlear implant at the noise side was turned off. The squelch effect was investigated for the patients' best performing ear and for the left and right ears separately. Results: In 13 individual patients, a squelch effect was present after 1 year. This number increased during follow-up years. On group level, a squelch effect was present in patients' best performing ear after 2 and 3 years (1.9 dB). A squelch effect was present in both ears after 3 years (AS: 1.7 dB, AD: 1.3 dB). Conclusion: Patients who underwent simultaneous bilateral cochlear implantation developed a measurable benefit from the squelch effect after 2 years in their best performing ear and after 3 years in both ears. These observations suggest that the brain learns to use interaural differences to segregate sound from noise after simultaneous bilateral cochlear implantation. The squelch effect increased over time which suggests a growth in cortical integration and differentiation of inputs from bilateral CIs due to brain plasticity. Trial Registration: Dutch Trial Register NTR1722. Level of evidence: 1b. Copyright (C) 2016 by Otology & Neurotology, Inc. Image copyright (C) 2010 Wolters Kluwer Health/Anatomical Chart Company

from #Audiology via xlomafota13 on Inoreader http://ift.tt/2bSB5sO
via IFTTT

Book Review.

No abstract available

from #Audiology via xlomafota13 on Inoreader http://ift.tt/2csA3t1
via IFTTT